Small Fiber Laser User Guide 2000W
- Small Fiber Laser
User Guide
2000W
Wuhan Raycus Fiber Laser Technologies Co., Ltd. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
TABLE OF CONTENTS
1 Safety Information……………………………………………………………………………………………………….1
1.1 Security Identifiers…………………………………………………………………………………………………..1
1.2 Laser Safety Grade…………………………………………………………………………………………………. 1
1.3 Security Identifiers…………………………………………………………………………………………………..2
1.4 Optical Safety………………………………………………………………………………………………………… 3
1.5 Electrical Safety………………………………………………………………………………………………………3
1.6 Other Safety Rules…………………………………………………………………………………………………..3
2 Product Description……………………………………………………………………………………………………..4
2.1 Features………………………………………………………………………………………………………………….4
2.2 Model description……………………………………………………………………………………………………4
2.3 Package accessories…………………………………………………………………………………………………5
2.4 Unpacking and Inspection……………………………………………………………………………………….. 5
2.5 Operation Environment…………………………………………………………………………………………… 5
2.6 Attentions……………………………………………………………………………………………………………….7
2.7 Specifications………………………………………………………………………………………………………….7
3 Installation…………………………………………………………………………………………………………………11
3.1 Dimensions………………………………………………………………………………………………………….. 11
3.1.1 Overall dimensions of RFL-C2000 small laser…………………………………………………… 11
3.2 Size and installation of output optical cable………………………………………………………………12
3.2.1 RFL-C1000 ~ RFL-C2000 Output Optical Cable……………………………………………….. 12
3.3 Cooling system installation and requirements……………………………………………………………13
3.4 Installation rules…………………………………………………………………………………………………….14
4 Using the Product……………………………………………………………………………………………………… 16
4.1 Front panel……………………………………………………………………………………………………………16
4.2 Rear Panel…………………………………………………………………………………………………………….16
4.3 Power Connection………………………………………………………………………………………………….17
4.4 Interface definition…………………………………………………………………………………………………18
4.4.1 Control interface……………………………………………………………………………………………..18
4.4.2 RS-232 serial port……………………………………………………………………………………………19
4.4.3 Ethernet TCP / IP interface and connection steps……………………………………………….. 21
4.5 Installation Instruction……………………………………………………………………………………………23
4.6 Start operation sequence…………………………………………………………………………………………24
4.7 Control mode selection…………………………………………………………………………………………..25
4.7.1 Control mode wiring diagram……………………………………………………………………………25
4.7.2 Stand-alone mode (internal control mode) (connect 4.6 in sequence)……………………. 26 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
4.7.3 External control mode (sequentially connected to 4.6)………………………………………… 26
4.7.4 AD Mode………………………………………………………………………………………………………. 27
4.7.5 controlling time-series chart…………………………………………………………………………….. 28
4.7.6 Red Light Control……………………………………………………………………………………………29
4.8 Turning off the laser:…………………………………………………………………………………………….. 29
5 Common Alarms and solutions………………………………………………………………………………….. 30
5.1 Alarm display………………………………………………………………………………………………………..30
5.2 Alarm processing…………………………………………………………………………………………………..30
6 Warranty, Return and Maintenance………………………………………………………………………….. 33
6.1 General Warranty…………………………………………………………………………………………………..33
6.2 Limitations of Warranty………………………………………………………………………………………… 33
6.3 Service and Repair…………………………………………………………………………………………………34 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Safety Information 1
1 Safety Information
Thank you for choosing Raycus fiber laser. This User Guide provides
important safety, operation, maintenance and other information. Please read it
carefully before using this product. To ensure safe operation and optimal
performance of the product, please follow all warnings, cautions, operating
procedures and other instructions accordingly.
1.1 Security Identifiers
WARNING: Describes a hazard that leads to a personal
injury or death.
CAUTION: Describes a hazard that leads to a minor
personal injury or product damage.
1.2 Laser Safety Grade
This series of lasers are classified as a high power Class 4 laser instrument
accounting to the European community standards EN 60825-1, clause 9. This
product emits invisible laser radiation at wavelength of 1080 nm, and the light
power is 100-2000W (depending on the model). Under such high power of laser
radiation, it may cause damages to the eyes or skin directly or indirectly. Despite
the radiation being invisible, the beam may cause irreversible damages to the retina
and cornea. Therefore, appropriate and approved laser goggles must be worn all
the times when the fiber laser is operating.
WARNING: Users must use appropriate laser goggles
when operating this device. The laser goggles are selected
according to the range of wavelength emitted from this
product. Users must select the appropriate laser goggles
according to the entire range of laser wavelengths. Please do
not directly look at the fiber delivery cable connector when
laser is powered on. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Safety Information 2
1.3 Security Identifiers
Raycus CW Fiber Lasers have different locations of safety identifiers
depending on the model, as shown in Figure 1:
Figure 1 Laser Security Identifiers
Laser safety identifiers include: safety warning, laser fiber delivery cable
connector warning, product certification, ID label, etc. The detailed descriptions of
the security identifiers are as follows:
Table 1 Security Identifiers
1: Fiber Delivery
Cable Connector
2: Type 4 Laser
Product
3: Class 2M Laser Product
Label-1mW Red Laser
4: CE Authentication 5: ID Label
6: Laser Radiation
Hazard
7: Electrical
Hazard
1
6
2 4
7 5 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Safety Information 3
1.4 Optical Safety
Any dust on the end of the collimator assembly can burn the lens.
CAUTION: DO NOT emit when the protective cap is
not opened, otherwise the lens or crystal will be damaged.
1.5 Electrical Safety
1)Make sure the product is firmly grounded through the PE line of the power
cord.
WARNING: Any interruption from the protective earth
will electrify the enclosure, which may result in personal
injury for operators.
2)Make sure that the correct voltage of the AC power source is used.
CAUTION: Wrong wiring mode or power supply
voltage will cause an irreversible damage to the fiber lase.
There are no components that need to be used by operator in the laser.
Please do not try to open the laser housing, otherwise it may cause electric
shock and the warranty will be invalid accordingly.
1.6 Other Safety Rules
1)
Do not directly look the laser fiber delivery cable connector when laser emitting.
Avoid using the laser in a dark environment.
2)Do not use fiber lasers in dark environment.
3)If this device is used in a manner not specified in this document, the protection
provided by the device may be impaired and the warranty will be voided.
4)There are no user serviceable parts, equipment or assemblies inside the product.
All service and maintenance shall be performed by Raycus. In order to prevent
electric shock, please do not break the seal or uncover the shield. Failure to
comply with this instruction will void the warranty. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 4
2 Product Description
2.1 Features
Raycus fiber laser, compared with traditional laser, has higher electro-optical
conversion efficiency, lower power consumption and more excellent beam quality.
It is compact and ready to use. Because of flexible laser output mode, it can be
easily integrated with the device.
Main Features:
Excellent beam quality
High reliable and sealing
High power stability
Power continuously adjustable and fast switch response
Maintenance-free operation
High Electro-optical Conversion Efficiency
Anti-reflection Capacity
High modulation frequency and editable waveform
Applications:
Welding、5G、Infrastructure
3D printing
Laser research
2.2 Model description
Raycus continuous wave laser includes 100, 200L, 200, 300L, 300, 500, 750,
1000,1500 and other models, which respectively represent 100W, 170W, 200W,
250W, 300W, 500W, 750W, 1000W and 1500W lasers. The definitions of the
model code are shown in the table below:
Table 2 definition of model code
1 RFL-C series continuous wave fiber laser - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 5
2
Power indicator, including 100, 200L, 200, 300L, 300, 500, 750, 1000,
1500W respectively representing 100W; 170W; 200W; 250W; 300W;
500W; 750W; 1000W; 1500 power laser
3 Wavelength, ‘B’ represents a wavelength of 1080nm
4
Output cable length, unit meter, including 15 meters and 20 meters, also can
be customized length
5 Cooling method, ‘W’ stands for water cooling, ‘A’ stands for air cooling
Notes: RFL-C100 ~ RFL-C3000 laser without air conditioning
2.3 Package accessories
Please refer to package accessories are in the packing box.
2.4 Unpacking and Inspection
Raycus fiber laser is delivered with the specially designed package to offer
the fiber laser maximal safety. Nevertheless, in order to prevent the occurrence of
unpredictable circumstances during the transportation, please inspect all packaging
once receiving the delivery. If you find any evidence of mishandling or damages,
please keep the damaged material and contact the shipping agent and Raycus
immediately.
Please double check if each listed contents is inside the package; and contact
Raycus as soon as possible if there is any issue.
Take extra care when removing the unit from the package to make the fiber
optic cable stay away from collision and vibration. Please do NOT distort, bend or
pull the output cable when unpacking the device; and avoid any collision to the
fiber delivery cable connector.
CAUTION: The fiber optic cable and fiber delivery cable
connector are precise optic instrument, ANY vibration or
impact to the fiber delivery cable connector, and twist or
excessive bend to the cable will damage the instrument.
2.5 Operation Environment
The operation conditions are listed as the following table:
Table 3: The Operation Environment Conditions for the Laser
Model 2000 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 6
Power
Voltage(V)
380±15% V AC
50/60Hz
Power Capacity
(kW)
6.1
Installation
Environment
Flat and no vibration
Ambient
Temperature
(℃)
10~40
Relative
Humidity (%)
<70
Warning:
1)Make sure the product is properly grounded before use.
2)The fiber delivery cable connector is connected with fiber optic cable.
Please inspect the fiber delivery cable connector carefully to prevent dust or
other contaminations. Use appropriate lens paper to clean it if necessary.
3)Failure to follow the instructions when operating the laser may cause
malfunction and damage.
4)It is not allowed to install the fiber delivery cable connector when the laser
is in operation.
5)Do not look into the fiber delivery cable connector directly. Wear
appropriate protective eye glasses all the time when operating the laser.
Do not expose this product to high humidity (humidity>
95%).
Do not allow this product to operate at a temperature
below the ambient dew point. (As shown in Table 4)
Table 4 Comparison table of constant dew point at ambient temperature and
relative humidity
Constant dew point table at ambient temperature and relative humidity
Ambient
temperature
(℃)
Maximum relative humidity
20% 30% 40% 50% 60% 70% 80% 90% 95%
20 -3.5 2 6 9 12 14.5 16.5 18 19
25 0.5 6 10.5 14 16.5 19 21 23 24 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 7
30 4.6 10.5 15 18.5 21.5 24 26 28 29
35 8.5 15 19.5 23 26 28.5 31 33 34
40 13 20 24 27.5 31 33.5 36 38 39
Laser operating temperature range
2.6 Attentions
1) Make sure that the correct voltage (according to Table 3) is used before
connecting AC current. Failure to connect power supply will damage the
device.
2) Failure to operate the laser in accordance with the control or adjustment
methods specified in this manual may cause damage.
3) For the output laser collimated by the collimating lens, it is important to
keep the collimating lens clean, and otherwise it will damage the device.
4) Please cap the fiber delivery cable connector when it is not in use. Do not
touch the output lens at any time. Use appropriate lens paper and alcohol
to clean it if necessary.
5) Failure to follow the instructions may cause laser power loss, and such
loss is not covered by warranty.
2.7 Specifications - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 8
Table 5 Product Specifications
Model C2000 C2000H Test Conditions
Optical Characteristics
Output Power(W) 2000
Operation Mode CW/Modulated
Polarization State Random
Power range(%) 10~100
Central Wavelength
(nm)
1080±5 Nominal Output Power
Output Power
Instability (%) ±1.5
Nominal Output Power;
Duration: ≥5hrs;
Ambient Temp.: 25±1℃
Modulation
Frequency(Hz)
50~20,000 Nominal Output Power
Red Laser output
Power(mW)
0.5~1
Optical Output Characteristics of IQB head
Beam Parameter
Product (BPP,
mm•mrad)
BPP <1.5 (mm×mrad) Nominal Output Power,4σStandard - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 9
Half Angle Divergence
(rad)
/ ≤0.06 Nominal Output Power,
4δStandard
Beam quality (M²) 5~6 /
Core Fiber(μm) 50(100、200 are optional)
Delivery Cable (m)
() ()
20 10 Customizable length
Electrical Characteristics
Power Supply 380±
15% V AC、50/60Hz
Max. Power
Consumption(W)
6100
Control Mode RS-232/AD/Ethernet
Other Characteristics
Dimensions(W×H×D)
(mm)
414×686×158(include handle)
Weight(kg)
<50
Operating Ambient
Temperature (℃)
10~40
Humidity(%) <70 - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Product Description 10
Storage
Temperature(℃)
-10~60
Cooling Method Water Cooling - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Installation 11
3 Installation
3.1 Dimensions
3.1.1 Overall dimensions of RFL-C2000 small laser
Figure 2 shows the dimensions of the RFL-C2000 laser.
Figure 2 (a) Front view (Unit: mm)
Figure 2 (b) Rear view (unit: mm) - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Installation 12
Figure 2 (c) Top view (Unit: mm)
3.2 Size and installation of output optical cable
Raycus continuous wave fiber laser uses different laser output cables
according to different laser models.
3.2.1 RFL-C1000 ~ RFL-C2000 Output Optical Cable
The output cables of Raycus RFL-C1000 ~ RFL-C2000 small lasers are
self-made IQB output cables. The specific appearance dimensions are shown in
Figure 4 below:
Figure 4 Dimensional drawing of IQB output optical cable - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Installation 13
For IQB output optical cables, the two copper contacts
(InterLock pins) on the fiber delivery cable connector must be
shorted before the laser works, otherwise the laser will not
work properly. Usually the copper contacts are automatically
shorted after the output fiber cable is installed in the processing
equipment.
Before installing the output cable in the processing head, the
lens of the output cable must be inspected. If the lens is dirty, it
must be cleaned.
It is forbidden to disassemble the output lens by anyone other
than Raycus, otherwise the warranty will be invalid.
3.3 Cooling system installation and requirements
Table 6 Cooling System Requirements
Model 2000
Cooling Capability (W) >6000
Minimum Flow (L/min) 20
Maximum Pressure (Bar) 7
External diameter of pipe
(mm)
13
Cooling system water
temperature (℃)
22±1℃
1) Temperature setting of cooling water:
Chiller 22±0.5℃(it does not have to be changed in summer)
2) Requirements on Cooling Water:
Purified water should be used.
In order to prevent the growth of mold that may lead to blockage,
adding alcohol solution to about 10% of the total volume is
recommended. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Installation 14
If ambient temperature is between -10℃ and 0℃, we recommend to
use 30% alcohol(volume ratio), and replace it every 2 months.
If ambient temperature is below -10℃, the chiller with both heating
and cooling functions must be used, and keep it in full-time operation.
3) Other cooling system requirements:
Check the entire water system and joints for leaks when starting the
cooling system the first time. The external water pipe must be installed
and connected according to the water inlet (IN) and water outlet (OUT)
indicated according to the laser, and otherwise the laser may not work
properly.
If the laser is not used for a long time, the cooling system and the
cooling water inside the laser should be drained, otherwise it will
cause irrecoverable damage to the laser.
Set the water temperature of the cooling system correctly
according to the ambient temperature. If the water
temperature is set too high, the laser will not work properly.
If the water temperature is set too low, condensation will
occur inside the laser or the laser output cable, which will
cause irrecoverable damage to the laser.
Before staring the laser, the cooling system must work
properly and the water temperature reaches a suitable
temperature.
3.4 Installation rules
1) Place the product in an appropriate position, immobilize it if necessary.
2) Check if the power supply has the correct voltage (laser model and
power voltage refers to product parameters in Table 5 ), and ensure the
earth line is firmly connected..
3) Connect the power cable and control cable to the product when power
supply is OFF. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Installation 15
4) Connect the cooling system to the laser and output fiber cables according
to the water inlet and outlet signs.
5) Please check the laser fiber delivery cable connector and do the
necessary cleaning before installing it in the device. If you find that there
is dust or foreign objects that cannot be cleaned, please contact Raycus
in time, and do not continue installation and operation for the time being.
6) Prevent the delivery cable from treading, pinching or excessive bending
yellow / metal armor protective sleeve during installation.
7) Please handle the laser output cable carefully, and do not receive
vibration during the installation and disassemble.
8) Make sure the environment is clean, or the fiber delivery cable connector
may be contaminated. It is prohibited to use fan during installation,
which will cause dust in the air.
9) The minimum bending diameter of the transmission cable of the laser
shall not be less than 20cm in the non-working state (such as transport
and storage). The minimum bending diameter should not be less than
30cm when the laser is working.
CAUTION: All the cables can only be connected when
power supply is off. Hot plug may damage the device.
Ensure that the laser output optical cable must be placed in a
natural state as far as possible, and it is forbidden to twist the
output optical cable
If the winding diameter of the output optical cable is too
small, the laser will be damaged
Before the laser output cable is assembled, the lens and the
cutting head cavity must be clean and free of pollution.
Keep the protective cap properly, prevent it from
contamination; or the aperture will be contaminated when
capped. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 16
4 Using the Product
The Raycus continuous wave laser (with network port) has
stopped using the super terminal. After the laser is powered on, there
is no display on the super terminal. Please log in to the official website
of Raycus to download the new version of the upper computer
software and upper computer software instruction manual.
Web:http://www.raycuslaser.com/index.php/index-show-tid-53.html
4.1 Front panel
Figure 5 shows the front panel style of RFL-C1000 ~ RFL-C2000 welding
laser (taking RFL-C1000 as an example, the front panel styles of other products are
the same):
Figure 5 RFL-C1000 laser front panel
4.2 Rear Panel
Figure 6 shows the rear panel style of the RFL-C2000 welding laser.
Figure 6 RFL-C2000 laser real panel
1. Alarm:Laser fault indicator lamp - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 17
2. Laser:Laser output indicator lamp
3. Power : The laser power indicator lamp is on, indicating that the laser is
powered on.
4. Water pipe joint: Pagoda joint, insert the quick-plug water pipe with an outer
diameter of 16 into the pagoda head and fasten it with a clamp to connect the
laser to the circulating cooling water.
5. Interface:Laser external control interface, see [4.4 Interface and Definition]
6. RS232:232 serial interface used for communication between laser and host
computer.
7. ETHERNET:Ethernet interface for communication between laser and upper
computer.
8. Power: Rocker switch for turning on the laser main power.
9. AC INPUT:Power line input
4.3 Power Connection
Before connecting the AC power supply, please check
whether the laser model and the AC power supply provided
are consistent with those listed in Table 3 or table 5. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 18
Table 7 Power connection requirements
Model RFL-C2000
Power
supply
380±15% V AC
50/60Hz
Power cord
Power cord
end
Four strands, marked L1, L2,L3 and PE respectively
Label
description
L1->Phase line (brown)
L2 -> Phase line (gray)
L3 -> Phase line (black)
PE->Protective earth wire (yellow green)
Note
Insert the plug at the end of the power cord into the socket marked “AC INPUT”
on the rear panel. Note that the plug has anti-reverse connection function. After
plugging it in, lock it with a lock.
4.4 Interface definition
4.4.1 Control interface
Figure 7 shows the DB25 control interface diagram:
Figure 7 DB25 control interface
The pin definitions of DB25 are as follows:
Table 8 Control interface definition
PIN NAME
Input
and
output
Function Typical Min MAX
Electric
current
2
Reserve
interlock Short
circuit
3
Reserve
interlock
8
Reserve
long-dista
nce power
supply
Short
circuit
9
Reserve
long-dista
nce power - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 19
supply
10
Reserve
emergency
stop
Short
circuit
12 Analog
Analog
input
External analog
quantity setting
0-10V
0V
(0%)
10V
(100%)
<10mA
13
Laser
Power
Analog
output
Optical power signal
output
0V
(0%)
3.3V
(100%)
<10mA
14 AGND
Analog
ground
12, 13 feet return 0V
15 MOD+
Digital
input
Laser modulation
signal
5-24V 5V 24V <10mA
16 MOD-
Return
port
15 feet return 0V
17 Red Laser
Digital
input
Red light control 5-24V 5V 24V <10mA
18 Laser EN
Digital
input
Laser enable 5-24V 5V 24V <10mA
19 Ready
Digital
output
Laser ready EVCC <100mA
20 EGND
Digital
ground
17, 18, 21 feet return 0V
21 EX_RST
Digital
input
Laser fault reset 5-24V 5V 24V <10mA
22
Laser
Error
Digital
output
Laser ready EVCC <100mA
23 EVCC
Digital
input
External voltage for
output of Ready and
Error signals
5-24V 5V 24V <100mA
Other NC
Not allowed to
connect
Please check the level of the control signal to ensure
compliance. Exceeding voltage or voltage fluctuations may
damage the laser
Please ensure that the analog signal DOES NOT exceed
10V, or product may be damaged.
Please use 2 and 3, 8 and 9, 10 and 11 through short circuit.
4.4.2 RS-232 serial port
The following figure shows the RS-232 serial port - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 20
Figure 8 RS232 serial port
Each pin is defined as follows.
Table 9 RS-232 serial port definition
Model Definition
2 RX
3 TX
5 GND
others None
A three-core (RxD, TxD, GND) crossing line is used. For specific commands
and descriptions, please refer to the software manual of the host computer or ask a
Raycus technician for a communication protocol. The specific parameter settings
of the RS-232 control interface are as follows:
Table 10 RS-232 interface configuration parameters
Parameters Set up
Baud rate 9,600
Data bits 8
Stop bit 1
polarity None
Flow control None
Figure 9 RS-232 serial cable configured for the product
Figure9 RS-232 serial cable - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 21
4.4.3 Ethernet TCP / IP interface and connection steps
The default IP address of the laser is 192.168.0.10 and the laser only supports
UDP communication and communication port 8099. The command must be sent as
a single string in a single packet.
Table 11 Ethernet interface pin definition
PIN Feature Description
1 TX+ Transmit Data+
2 TX- Transmit Data-
3 RX+ Receive Data+
4 N/C Not Connected
5 N/C Not Connected
6 RX- Receive Data –
7 N/C Not Connected
8 N/C Not Connected
If conditions permit, please use this interface first to get better communication
stability.
Ethernet connection steps:
First Step: Open Raycus PC software,
click “Session→RS232(or Ethernet)”to
make the host computer communicate with the laser, and then click “Tool →
Laser IP Set” to enter the laser IP address setting;
Second Step:The default password is “1122334455667788”. After passing the
verification, read or set a new laser IP address.
Third Step: If you use the upper computer software of Raycus to control the
laser, you need to find the folder where the upper computer software is located,
open the laser configuration file config.xml, and write the newly set IP address of
the laser; if you do not use the upper computer of Raycus, please directly enter the
fourth step;
Fourth Step: Configure the Ethernet network connection on the PC side, select
“Use the following IP address:”, and manually assign the IP address. The PC side - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 22
IP address must be on the same network segment as the laser IP address, and
assign a subnet mask address. The default is 255.255.255.0. Click the “OK” button
to confirm the settings and exit. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 23
Figure 10 Ethernet connection steps
4.5 Installation Instruction
1) Take out the laser carefully, move it to the installation position, remove
the handle, and use the handle to install the hole position to fix it with
screws.
2) Remove the protection cap of the fiber delivery cable connector, use
strong light to check if there is dust on the lens of the output end. If so,
please clean it before use, and then cover the protection cap of the fiber
delivery cable connector.
3) Install the output optical cable on the processing equipment according to
the actual situation (also install the fiber delivery cable connector cooling
water pipe), pay attention to arrange the output optical cable, and protect
the fiber delivery cable connector. After installing and arranging the - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 24
output optical cable, remove the protective cap, and check whether the
output lens is clean again, and then install the fiber delivery cable
connector;
4) Connect the laser cooling water pipe;
5) Connect the control line and power supply according to the control mode.
4.6 Start operation sequence
Make sure the rocker switch is off. All electrical connections must be completed
before the laser is powered on.
1) Turn on the chiller and check the water pipe for leaks. If there is no
leakage, turn off the chiller and wait for the laser to turn on.
2) Close the rocker switch on the rear panel and wait for the laser to power
on and perform a self-test.
Note: When the working environment temperature and relative humidity are within
the dew point area (blue) in Table 4, for RFL-C100 to C3000 type lasers, please
improve the working environment of the laser to avoid damage to the laser due to
condensation. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 25
4.7 Control mode selection
4.7.1 Control mode wiring diagram
Figure 11 Wiring diagram in RS-232 mode
Note: The above modes need to be modified by raycus upper computer to turn off the red
light external control, external light output enable and external AD, and only the modulation
mode is reserved.
Figure 12 Wiring diagram in AD mode
Laser
Control card
AC input/
regulator
Laser
AC input/
regulator
Control card
External red laser control
external enable - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 26
4.7.2 Stand-alone mode (internal control mode) (connect 4.6 in sequence)
1) Turn on the rocker switch, and the panel “power” indicator light is on
2) Wait for 20s, internal main control board circuit initialization is
completed.
3) Turn off all external control mode of the laser (turn off external control of
red laser, external light emitting enable, external AD and modulation
mode )
4) Set the power of the laser (the laser power is to be set by 0-10V analog
quantity, when the AD mode is on; and to be set by the serial port or
Ethernet, when the AD mode is off).
5) Turn on the laser enable
6) The serial port or the Ethernet interface sends a shutter opening command
to output the laser, and sends a shutter closing command to turn off the
laser.
Shutdown the laser, please refer to 4.8
4.7.3 External control mode (sequentially connected to 4.6)
Modulation: When the duty cycle of the laser’s internal frequency is
set to 100%, the laser works in external modulation mode. The on and off
of the laser is controlled by the “modulation” signal provided by the user
from the external MOD interface. For the timing diagram, see [4.7.5
Control timing Figure];
Gate mode:If the duty cycle of the laser’s internal frequency is less
than 100%, the laser will work in internal modulation mode. The laser is
turned on and off by the user from the external MOD signal and internal
frequency generator. Stop internal pulse occurring, see [4.7.5 Control
Timing Diagram] for timing diagram; - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 27
The laser works in external modulation mode by default after power
on.
5) Turn on the rocker switch, and the panel “power” indicator light is on
6) Wait for 20s, internal main control board circuit initialization is completed
7) Set laser power (laser power is set by 0-10V analog when AD mode is
enabled, laser power is set by serial port or Ethernet when AD mode is
off)
8) Send a light enable signal to the laser in one of the following ways
●Interface gives light enabling signal (connect 24V between pin18 and
pin20)
●serial port or Ethernet interface to issue the shutter open
command-enable light
9) The On/Off of the laser is controlled by the “modulation” signal provided
by the external mod interface;
Shutdown the laser, please refer to 4.8
4.7.4 AD Mode
The laser enters the external AD mode through the upper computer selection.
The laser power is controlled by the voltage between pin12-14 of DB25 control
interface (0v-0% power, 10v-100% power).
If the upper computer selects external AD mode off, the laser power is set by
serial port or Ethernet, and the Raycus hand-heldwelding laser will enter external
ad mode by default when powered on. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 28
4.7.5 Controlling time-series chart
Figure 13 Standalone mode—Continuous sequence diagram
Figure 14 Standalone mode – Pluse sequence diagram - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Using the Product 29
Figure 15 Modulation—sequence diagram
Figure 16 Gate mode –sequence diagram
4.7.6 Red Light Control
Turn on the rocker switch, the green “POWER” indicator light is on. Waiting
for 20s, the laser enters the red-light external control mode, and a high level of
5-24V is given before the 17-20 feet. If red light internal control is selected on the
host computer, you can use the host computer to click “red light on” to turn on the
red light.
Laser and red indicator light can be output
simultaneously.
4.8 Turning off the laser:
Please turn off the laser in the following sequence
1) Turn off the laser output enable
2) Turn off the rocker switch
3) Turn off the chiller
4) If the laser is not equipped with air conditioner, please ignore this
step; If it is equipped, please wait for the air conditioner to continue
working for 10min;
5) Put on the fiber delivery cable connector protection cap. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Common Alarms and solutions 30
5 Common Alarms and solutions
5.1 Alarm display
Connect the computer and open the PC software (download the PC software
and its instruction manual, please log on the Raycus official website), after the
laser and client software establish normal communication. All laser alarm states
can be displayed on the client software interface, as shown in Figure 17. The laser
will give an alarm in the case of abnormal internal temperature, abnormal output
power, abnormal power supply, abnormal condensation, etc.
Figure 17 main interface of upper computer software
When the laser is working and any alarm occurs (except the abnormal
interlock), the upper computer software interface will also display the alarm. At the
same time, the alarm light (yellow) on the laser panel will be on, and the laser will
stop and lock.
5.2 Alarm processing
The instructions and possible solutions of alarms are as follows: - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Common Alarms and solutions 31
Table12 Alarm instructions and possible solutions
Alarm message Alarm instructions and possible solutions
System Timer
Alarm
Instruction:
Internal clock abnormal
Solutions:
When this alarm occurs, please contact Raycus directly
Laser On Button
Alarm
Instruction:
This alarm occurs when the light exit button on the front panel
of the laser has been pressed before powering on.
Solutions:
When this alarm occurs, please power off the laser and make
the light enable button pop up, and then power on the laser
again to cancel the alarm. If the alarm continues to occur,
please contact Raycus.
Inter Lock Alarm
Instruction:
Occurs when the laser InterLock is disconnected
Solutions:
Short the InterLock pins. If this error continues to occur, please
contact Raycus.
Current Driver
Alarm
Instruction:
Internal constant current driver is error
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
Laser OutAlarm
Instruction:
The laser will get this alarm when it cannot detect any laser
light signal. Laser out alarm occurs only when the laser is
emitting light
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
Laser Power Alarm
Instruction:
The alarm is generated when the emission of the laser cannot
reach the set value. Power alarm occurs only when the laser is
emitting light.
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
ACDC1 Alarm
Instruction:
AC/DC1 Alarm. Laser power supply out of work or sudden
power disconnect of the power supply system may cause the
alarm - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Common Alarms and solutions 32
Solutions:
Check whether the input AC voltage is normal. Restart the
laser to try when it is normal. If the alarm continues to occur,
please contact Raycus.
ACDC2 Alarm
Instruction:
AC/DC2 Alarm. Overcurrent or overvoltage inside the device
may cause this error.
Solutions:
Check whether the input AC voltage is normal. Restart the
laser to try when it is normal. If the alarm continues to occur,
please contact Raycus.
T1/T2 Alarm
Instruction:
Laser low / high temperature alarm occurs when the sensor in
the laser detects that the internal temperature of the laser is
abnormal. A high-temperature / low-temperature error occurs
when the temperature at the monitoring point exceeds the set
upper / lower limit.
Solutions:
High temperature alarm.
Check whether the water-cooling system is normally working,
the water temperature is set correctly, and also the water
connection is correct. When the water cooling system works
normally and the water temperature drops below 30°C, restart
the laser. If the alarm continues, please contact Raycus.
Low temperature alarm.
Check whether the actual water temperature of the water is too
low. In addition, a low ambient temperature may also cause a
low temperature alarm when the laser is cold. Please wait until
the water temperature of the water rises above 10°C and then
restart the divice. If the alarm continues, please contact Raycus.
Hum Alarm
Instruction:
The laser detects that the current temperature of the
water-cooled plate is lower than the current dew point
temperature of the laser. There is a risk of condensation.
Solutions:
Stop using the laser immediately. For RFL-C100 ~ RFL-C1000
lasers, please improve the working environment so that the
ambient temperature is lower than the internal temperature, and
then restart the laser (recommended to configure a separate
air-conditioned room for the laser). For the RFL-C1500S /
C2000S laser, please wait 30 minutes for the air conditioner to
run, and then restart the laser. If the alarm continues, please
contact Raycus. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Warranty, Return and Maintenance 33
In addition to the above, if there are any other questions or errors, please
contact Raycus to get help.
6 Warranty, Return and Maintenance
6.1 General Warranty
After all the products manufactured are delivered according to the order or
specifications, Raycus will guarantee the products with material and technical
problems and ensure that they meet the specifications under normal use.
Raycus has the right to selectively repair or replace any products with material
or technical problems during the warranty period. All products repaired or replaced
during the warranty period are guaranteed free warranty only for those products
with special problems. Raycus reserves the right to charge the payment for the
products with problems under normal use.
6.2 Limitations of Warranty
The warranty does not cover the maintenance or reimbursement of our
product of which the problem results from tampering, disassembling, misuse,
accident, modification, unsuitable physical or operating environment, improper
maintenance, damages due to excessive use or not following the instructions
caused by those who are not from Raycus. The customer has the responsibility to
understand and follow this instruction to use the device. Any damage caused by
fault operating is not warranted. Accessories and fiber connectors are excluded
from this warranty.
According to the warranty, client should write to us within 31days after the
defect is discovered. This warranty does not involve any other party, including
specified buyer, end-user or customer and any parts, equipment or other products
produced by other companies.
WARNING: It is the customer’s responsibility to understand and
follow operating instructions in this User Guide and specifications prior to
operation-failure to do so may void this warranty. Accessories and fiber
connectors are not covered by this warranty. - Wuhan Raycus Fiber
Laser Technologies Co., Ltd
User Guide of 2000W fiber laser
Raycus User Guide | Warranty, Return and Maintenance 34
6.3 Service and Repair
This product has no built-in parts for user maintenance, so all maintenance
should be carried out by Raycus technical personnel.
In case of any alarm during the use of the product, the technical personnel of
Raycus shall be informed in time and troubleshooting shall be carried out.
All repair or replacement products must be placed in the original packaging
box provided by Raycus, otherwise any product damage caused by this will not
be repaired free of charge by Raycus.
When you receive Raycus products, please check whether the products are
intact in time. If there is any abnormality, please contact the carrier or Raycus
in time.
Raycus will continue to develop new products. The product information
listed in the manual is subject to change without further notice. All technical
parameters are subject to the contract terms.
The above product warranty and service terms of Raycus are for users’
reference only, and the formal service and warranty contents are subject to
agreement in the contract.
© 2019 Wuhan Raycus Fiber Laser technologies Co. Ltd, All Rights Reserved.