Toshiba frequency inverter VF-S15 general purpose series

Toshiba VF-S15 features

Easy setting, Simple operation
– Easy setting, simple operation with the large dial
Just turn and push the large setting dial to browse and select the right parameter. The reference frequency can be also set by the large setting dial.

– Parameter can be set without power supply to the inverter
Using the optional parameter writer, you can read/write/ retain/set parameters. It is useful in case of incorporate numbers of inverters to the machine.

– Showing most frequently used parameter in EASY mode
EASY key allows you switch between EASY mode and Standard mode.
EASY mode: Scrolls through a list of most frequently used parameter.(32 parameters in maximum.)
Standard mode: Show all existing parameters.

Eco Design
– Long lifetime
Long life main-circuit capacitor is used to achieve 10 years lifetime design.
*Average ambient temperature 40˚C, load factor 80% or less, 24-hour and 365 days operation.

– Harmonize with environment
Compliance with the European RoHS Directive.
Built-in noise filters to suppress electromagnetic noise.
1-Phase 240V models and 3-Phase 500V models: Built-in EMC noise filter complies with the European EMC Directive.
3-Phase 240V models: Built-in basic noise filter.

– Side-by-side installation
Side-by-side installation is possible for all VF-S15 models. It means that you can further save space as two or more units can be installed in close proximity next to each other.

Energy savings & Powerful operation
– Along with the motor, achieve energy savings
High energy saving performance PM motor can be driven normally. Auto-tuning can set motor constant easily.
Energy saving mode for induction motor. Improve the energy saving effect of variable torque load such as fan and pump.

– Easy operation of high torque load
Vector control mode generate stable, high torque power from motor startup to a desired motor operating speed. Further, if you set the starting frequency to 0.1Hz, motor can start smoothly with strength.


* When a Toshiba standard 3-phase 400V-1.5kW motor is driven by the VFS15-4015PL-W after parameters are set.

Applicability
– Auto-tuning can setup motor constant easily
With vector control mode and PM motor control mode, auto-tuning function leads you easy access to motor constant setup and fully use of all the advantages of motor.

Motor information is required for the auto-tuning:
•Motor rated capacity (kW)
•Motor rated current (A)
•Motor rated speed (min-1)
•Motor rated Voltage (V) (In case of PM: Induced voltage(RMS between the line)
*Please find the information on the motor’s name plate.

– Easily adjust the lifting application by learning function
A learning function for setting and storing to memory required parameters while performing actual operations is also provided to facilitate adjustments. Every model is built-in braking resistor drive circuit.

Expandability of the system
– Built-in RS485 is equipped as standard
Modbus-RTU protocol /TOSHIBA protocol is complied. Communication speed: Maximum 38.4kpbs
– Variety of communication options
CC-Link, PROFIBUS-DP, PROFINET, DeviceNet™, EtherNet/IP™, EtherCAT®, CANopen®

Useful function and specification

Simplify the system
– Panel display control
Contents of your requests, such as load condition, could be viewed on the inverter’s panel. (Using the communications)

– Shows power by the pulse count
Integrated power can be output by the pulse. Even without the external wattmeter, power can be shown by the pulse count.

– Flexible terminals
The terminal function settings can be changed. Multiple input terminal functions can be assigned with single input terminal to simplify the external circuit.

Useful for OEM
– Parameters can be set easily
• Application easy setting
6 parameters for particular usages are available. Parameters match to your machine can be displayed and setup easily by using the application easy setting.

• Protection of the setting parameters.
VF-S15 provides protection for the setting parameters.
Four-digit password is required to reinforce the security.
VF-S15 can save and restore a set of parameters.
• Setting from extension parameter writer.
• Setting and management on a PC: PCM002Z

– Easy wiring
• Detachable control terminal board
Remove the terminal board to wiring efficiently.

Useful to building the system
– Control power supply backup
Control power supply is supplied from the inverter’s main circuit and also supplied by another input. It can maintain the output signal and trip indication, when the main circuit power supply circuit is also turned off due to inverter trip.

– Continuously adjustment from analog input
Can be adjusted continuously by analog input, the value to be set by the parameter.
< Adjustment parameters >
Acceleration/Deceleration time
Upper limit frequency
Torque boost value
Motor electronic-thermal protection level etc.
*For processing by the internal, parameter settings are not changed

International Standards
– Compliant with major international standards

– Sink/Source control logic
It can be configured for both sink logic and source logic.
– Built-in EMC filter
1-phase 240V and 3-phase 500V model have built-in noise filter complied with the European EMC Directive.
– Wide variety of applied conditions
Power supply: 240V class model is for 200~240V, 500V class model is for 380V~500V. It can correspond to a wide range of power supply
Ambient temperature: It can be used maximum ambient temperature of 60 degrees *¹
Altitude: Maximum altitude 3000 meter*¹
*1 The maximum output current may be limited depend on the operating conditions

Easy maintenance
– Monitor number of starting
Displaying number of starting and output the alarm signal are helpful for maintenance.
– Details on history trip records
Output current, input voltage etc, a monitor to identify the cause of the problem and help to find countermeasures. VF-S15 can keep memories of the last eight trips even after resetting.
– Tracing function

Safety function
Safety function prevents a disaster caused by a complex Machine, not only operator but also machine design regards to safety precaution. It is insulating the output reliability in the event of an emergency. And it can simply the system and reduce the wiring and external devices cost.

Compliant with safety standards:
Possible to disconnect the output corresponding to the safety standard.
•EN954-1 Category 3
•IEC61800-5-2/IEC61508 SIL2
•IEC62061 SIL2 CL
•ISO13849-1 Category 3 PL “d”
•IEC60204-1 Category stop 0, 1

PM motor drive technology
The VF-S15 can drive Interior Permanent Magnetic Motor(IPM) and Surface Permanent Magnetic Motor(SPM) for high efficiency, high torque energy saving, downsizing and lightening.

Dual rating (CT/VT)
The VF-S15 can be used the constant torque and variable torque applications by dual rating operation. For example, if variable application (fan and pump) required 15kW drives, it can be operated by 11kW rated of VF-S15.

– Constant torque application
The torque value of constant torque application require the high torque level of different motor speed for conveyors, Machine tools, Food machine and Elevator.

– Variable torque application
The torque value of variable torque application such as Fan, Pump and HVAC require low torque unit to operating speed.

My function
My function enhances programming capability to inverter’s input/output signals to respond to customer needs without external relays or a PC in some cases. Easy programming tool (PCL001Z) is available.

– Easy programming(PCL001Z)
My function parameter can be set easily by the PCL001Z

Communication
– Built-in
RS-485 communications: Modbus-RTU protocol/TOSHIBA protocol. – Network options
CC-Link
PROFIBUS-DP
PROFINET
DeviceNet™
EtherNet/IP™-Modbus TCP
EtherCAT®
CANopen®
*Registered trademark
CC-Link is Mitsubishi Electric Corporation DeviceNet is ODVA(Open DeviceNet Vendor Association) EtherNet/IP is ControlNet International, Ltd EtherCAT is Beckhoff AutomationGmbH CANopen is CAN in Automation.

– Operation·Management on a PC (Free software available) • Edit and monitor(PCM002Z)
The PCM002Z communication software allows you to edit, monitor, and trace parameter data on a PC, enabling easier data management from inverter startup through to maintenance.
• Data storage of the protection operation: Tracing function(PCT001Z)
Memorize and read out the data collected at the time of tripping or triggering. • Remote control
Using the EtherNet option, it can be remote controlled from PC.